Citat:
maks319:
What happens if piping is less than the minimum recommended length (3 metres / 5 metres)?
If the product is installed with less pipe work than the minimum requirement specified by Fujitsu engineers, noise and/or vibration issues may occur and also the system may not perform as well as it is designed to. Fujitsu will not cover warranty claims for issues caused by units not being installed in accordance with their manuals.
Stvarno treba da bude 3m :)
A lepo smo ti rekli isto to. Ajd' sad lepo prosledi taj odgovor ekipi koja ti je rekla da "nema veze", čisto da se zna da nemaju pojma. I obavezno javi potrošnju sa dužom instalacijom, i da li tako često ide u defrost. Potrošnja bi trbalo da bude bar malo manja, ali bi defrosti trebalo da budu MNOGO ređi. I gledaj da im ne iscuri gas kad budu skidali cevi, pa da onda nadopunjuju na manometre. Ukoliko bude trebalo dopunjavanje, zbog curenja pri skidanju cevi, mora SVE da se izvadi napolje, da se premeri tačna količina gasa na vagu, pa da se vrati u uređaj. Većina Fujitsu klima je na Eurovent-u testirana sa 5m instalacije, a 12LT npr sa 7m!
Fujitsu ASYG 12LTCA @30kvm + 2kom TA 2kW+2kW@30kvm. Izolacija spolja demit 8-10cm, tavanska ploča 10cm vuna.