Nasao sam podesavanja za moj sporet na osnovu ugradjene elektronike..
Po uputsvu u meniju coclea su vrednosti izrazene od 0-60[s] a kod mene su od 300-2700 necega?
menu cochlea
co1 ignition power 500
co2 stabilization power 600
co3 power 1 600
co4 power 2 900
co5 power 3 1200
co6 power 4 1600
co7 power 5 2000
co8 power 6 2000
co9 periodic cleaning power 0
c10 second ignition power 400
c11 modulation power 600
c12 nema ga u manualu 1000
po5 total time auger period 2700
p15 value of the "tempo auger on" 5%
p27 minimum auger time on 300
ventilator izduvnih gasova [rpm]
uo1 ignition power 2100
uo2 stabilization power 2200
uo3 power 1 1300
uo4 power 2 1500
uo5 power 3 1700
uo6 power 4 2050
uo7 power 5 2450
uo8 power 6 2500
U09 Periodic Cleaning Power 2700
U10 Second ignition power 1600
U11 Modulation power 1100
u12 nema u manualu 850
P23 Power off 2200
P14 Minimum speed of combustion fan 300
P30 Maximum speed of combustion fan 2700
P16 Correction step value of the values ??of the
Combustion fan speed 5[/code]
ventilator izduvni gasova 2
fo1 ignition power 0
fo2 stabilization power 40
fo3 power 1 110
fo4 power 2 120
fo5 power 3 130
fo6 power 4 150
fo7 power 5 170
fo8 power 6 180
fo9 periodic cleaning power 200
f10 Second ignition power 0
f11 Modulation power 100
f12 nema u manualu 0
f23 Power off 200
ventilator grejanja
fo1 power 1 100
fo2 power 2 100
fo3 power 3 100
fo4 power 4 100
fo5 power 5 100
fo6 power 6 100
po6 heating power
management 1; heating power equal to combustion
tajmeri
T01 Cleaning during ignition 15
T02 Glow plug preheating 60
T03 Ignition preload 20
T04 Fixed Ignition 1 180
T05 Ignition Variable 900
T06 Stabilization 180
T07 Periodic cleaning repeat 30
T08 Periodic cleaning duration 40
T09 High Voltage Safety Delay 1 5
T10 High Voltage Safety Delay 2 20
T11 Standby exit delay 10
T12 Delay for thermostat increase Pump running at Step nema u podesavanju
T13 Standby shutdown duration 200
T14 Timeout 60
T15 Safety shutdown 40
T16 Cleaning Off 200
T17 Power update 10
T18 Update of power from ignition 10
T22 Standby input delay 10
T23 Fuel tank filling timer 10
T24 Duration of lack of pellet signal if P44 and P48 = 1, 3, 4 or duration of fuel filling control if P44 or P48 = 2 20
T27 Auger 2 deactivation delay (if P44 or P48 = 1) 1 900 [s] T30 Work time Motor Cleaning 30
T31 Waiting time Motor Cleaning 1 600 [min} T40 Auger activation delay (if P44 or P48 = 1) 500
T41 Pump working time 20
T42 Maximum pump inactivity time 10
T43 Timer to switch from Modulation to Standby if boiler temperature> (Boiler Thermostat + D23) and A13 = 1 0 3600 [s]
T46 Valve working time 30
T66 System operating time before it goes to Block 0 20000 [hours] T67 System operating time before the Cleaning 0 message appears 20000 [hours] 0
T68 Delay for restoring the original value of the boiler thermostat in the event of a request for sanitary water 0 900 [s]
Mislim da je dozator peleta previse podesen, pogotovo kad sporet postigne temperaturu i radi u modulaciji. Okacicu i original fajl pa ako neko moze da pogleda i da mi kaze sta da podesim. Postoje jos podesavanja ako treba postavicu hvala. Pelet sam uzeo neki lokalni na preporuku ali sam probao i bioenergy point i sparrow i isto se prepunjava casa gde gori pelet
original fajl elektronike